Support for Network file paths Fixed problem with calibration lockup with certain sound cards Corrected channel label annotation on printouts Improved Peak Hold logic Fixed problem with creating peak hold overlays on the right channel Released version 5.1.0.16 Added new COM API automation function TriggerSetThreshold() Fixed problem exporting 8 bit wave files to binary format Released version 5.1.0.17 Added new COM API automation function TriggerSetThreshold() Fixed problem exporting 8 bit wave files to binary format Released version 5.1.0.17 " Added new Time series plot right click menu ""Save To Wave File"" - quickly create wave files from within a larger file." Fixed problem with network hardware key license timeout Released version 5.1.0.18 Fixed right channel y axis label problem on time series when independent calibration enabled Released version 5.1.0.19 Fixed right channel display of results when Compute RMS level right click command used. Reduced gap between channels when dual channel plot printed. Fixed lower limit on frequency span spin control in plot options dialog box Released version 5.1.0.20 Added Run Control option to automatically start all other instances of analyzer Released version 5.1.0.22 Added new calibration feature to quickly set the calibration reference point to 0.0 dBr. Right Click menu on Spectrum View ""Set Calibration to 0 dBr at this frequency. New DDE and API Commands to perform this action from an automation client or macro. Note - This will cause the analyzer to compute and apply calibration values that will result in a level of 0 dBr at the frequency corresponding to the mouse position. Use this to quickly normalize the trace such as when performing a frequency sweep test. Released version 5.1.0.23 Fixed problem with negative Leq values with certain settings. Added Frequency Zoom toolbar controls to Spectrogram and 3-D Surface Plots. Released version 5.1.0.24 Added Time Series right click menu ""Compute Peak to Peak Level. Released version 5.1.0.25 Added RT-60 utility options for 1/1 Octave or 1/3 Octave resolution. Released version 5.1.0.29 Added Run Control option to allow spacebar to toggle between Run and Stop Released version 5.1.0.30 Optimized Decimation for faster performance Fixed minor timing issues with run control timing when trigging used Released SpectraPLUS-SC version 5.1.0.34 Fixed problem decoding calibration values from Digiducer when Japanese character set used. Released SpectraPLUS-SC version 5.1.0.36 Added "Set or Create All Paths" option to dialog box. SpectraPLUS-SC version 5.1.0.37 Fixed Leq Update rate timing issue. SpectraPLUS-SC version 5.1.0.38 Added support for SpectraDAQ-200 Input Range and IEPE control Direct hardware and transducer calibration Support for embedded license key on DAQ SpectraPLUS-SC version 5.2.0.2 Fixed playback glitch issue when ASIO used Added new COM API functions: WritePlotToBitampFile() SetOverlay() ShowOverlay() HideOverlay() SaveOverlay() LoadOverlay() BuildSpectrogramPlot() BuildSurfacePlot() SetTimeSeriesPlotTimeSpan() GetDigitalInputLineState() SetDigitalInputLineState() SpectraPLUS-SC version 5.2.0.3 Added right click menu to Time Series plot Set Trigger Threshold SpectraPLUS-SC version 5.2.0.4 Fixed error message with Hyrdophone sensitivity calibration Added "DAQDeviceControl.exe" utility for controlling SpectraDAQ-200 input gain and IEPE for use with other sound card software SpectraPLUS-SC version 5.2.0.5 Fixed problem with THD vs Freq utility when high sampling rates used SpectraPLUS-SC version 5.2.0.6 Added support for Digiducer model 333D02 and MB63 Fixed problem with playback error (Device is in use) on some sound cards SpectraPLUS-SC version 5.2.0.7 Fixed scaling issue when transfer function is used with linear amplitude axis scaling Added the following right click menus to the Time Series plot: Compute Cumulative Sound Exposure Level (C-SEL) Export Peak Values to text File Added small square on each sample when zoomed in on the time series plot Fixed cursor positions when center frequency is not zero on the time series plot SpectraPLUS-SC version 5.2.0.8 Added File I/O option to store and display recording time stamp to the wave file Installer and application signed with digital certificate SpectraPLUS-SC version 5.2.0.9 Fixed bug with RT-60 when maximized and then closed Display a moving current position line on time series plot when commands are used SpectraPLUS-SC version 5.2.0.10 Fixed issue with missing audio when playback of short time segments SpectraPLUS-SC version 5.2.0.11 Fixed glitch on signal generator Added right click menu to time series "Compute RMS, Max, Min, and Peak to Peak levels" and added data table showing the results SpectraPLUS-SC version 5.2.0.12 Fixed signal generator randomly stopping Added logic to retain the name of last selected configuration file in main toolbar until any processing settings are changed SpectraPLUS-SC version 5.2.0.13 Fixed slight glitch with multitone signal generator in certain cases Fixed program hanging up when automatically begining a new wave file when time stamp is embedded Fixed startup issue with COM API with certain configurations SpectraPLUS-SC version 5.2.0.14 Fixed issue with data logging when Leq selected and Leq utility is not open Added capability to import to 32 bit wave files Show the available gain before clipping in the dialog box Fixed problem with toolbar when RT-60 is full screen Fixed issue when viewing existing RT-60 files with different sampling rates Added capability to display thick spectrum traces, overlays and markers on spectrum plot Fixed memory leak with certain overlay operations Enabled acceleration conversion list box when Digiducer is selected input device Added new API commands: SetInputDevice() SetOutputDevice() SetDAQInputGainAndIEPE() OpenMacroFile() RunMacro() StopMacro() PrintPlot() WriteSpectrumToTextFile() OpenTHDvsFreq() RunTHDvsFreq() SaveTHDvsFreq() CloseTHDvsFreq() SpectraPLUS-SC version 5.2.0.15 Fixed issue with macro utility edit control showing garbled data Fixed issue with print annotation edit control showing garbled data Optimized dynamic decimal place formating of plot axis labels Show overlay when user loads overlay file from disk Optimized time series plot vertical axis centering logic Optimized time series plot autoscale logic SpectraPLUS-SC version 5.2.0.16 Fixed issue with with stereo wave files SpectraPLUS-SC version 5.2.0.16A Fixed right channel logic error with Cummulative SEL plot Optimized DDE and COM API commands for setting mic compensation files Data Logging toolbar button underlined with red bar when enabled SpectraPLUS-SC version 5.2.0.17 Added ability to monitor the inputs with the outputs when using the DAQ Added new COM API commands: GetDelayFinderValue() SetCrossChannelDelayValue() SpectraPLUS-SC version 5.2.0.17A Added "Live Monitoring" feature to SpectraDAQ-200. This will route the input channels to the ouput channels to allow you to listen to the signal while the analyzer is running. Expanded error messages if failure opening sound card occurs. SpectraPLUS-SC version 5.2.0.18 Support for Digiducer model 485B39 Added option for THD vs Freq or THD+N vs Frequency Added overlay option to "Copy to Left/Right Channel" Added Load/Save to .tones file for Multiple tones signal generation Added API command "LoadGeneratorMultiToneFile()" SpectraPLUS-SC version 5.2.0.18a Increased number of decimal places for File Export, Copy data and other operations. Fixed issue with Level sweep when very short sweep times used Fixed issue with custom calibration axis labels being cleared in certain cases. SpectraPLUS-SC version 5.2.0.18b Improved THD vs Freq algorithm at low frequencies Fixed issue with missing labels when loading a calibration file Increased signal generator level lower limit from -96 dB to -144 dB Increased numerical precision of signal generator level edit control SpectraPLUS-SC version 5.2.0.18c ASIO support for sound cards with multiple channel pairs Improved dithering algorithm SpectraPLUS-SC version 5.2.0.18d Fixed crash when Real Time buffering disabled Fixed issue with "WaitTopOfMinute" Macro command Added "Pull Cursor to Peak Hold" feature to Spectrum Plot options Fixed issue with THD vs Freq when low frequencies are selected SpectraPLUS-SC version 5.2.0.19 Fixed issue with THD vs Freq utility when closing after full screen Fixed issue with 32 bit wave file calibration to dBFS Optimized frequency axis labeling when zoomed in to narrow span Changed axis label from dBr to dBFS for clarity Added Log threshold info to header when using Export Peak Values to File Added right click menu to I/O Device dialog box with ASIO debug and SpectraDAQ-200 debug info Fixed logic issue setting signal generator output level with SpectraDAQ-200 from COM API SpectraPLUS-SC version 5.2.0.20 Improved robustness when SpectraDAQ-200 and computer goes into sleep or hibernation Added Device option to put SpectraDAQ-200 into low power mode when application closes Improved frequency axis grid lines and labels when high sampling rates are used Optimized time axis tic marks in Spectrogram and 3D Surface plots Added calibration support for the Modal Shop 485B39 digital ICP device SpectraPLUS-SC version 5.2.0.21 Fix logic for enabling Calibration dialog controls for Digiducer SpectraPLUS-SC version 5.2.0.21A Fixed issue when calibrating to external reference signal and changing DAQ gain SpectraPLUS-SC version 5.2.0.21B Improved error message text if sound card cannot be accessed. Fixed glitch with User Defined signal generator option if stereo mode enabled SpectraPLUS-SC version 5.2.0.22 Now compiled with Visual Studio 2017 (C++) Added ability to read and write user metadata to wave file New menu and dialog box Option to prompt for Metadata when saving wave file Option to show metadata on plots when printing (print annotation dialog) New COM API commands: SetMetadata() GetMetadata() SetDecimationRatio() PerformHilbertTransform() Support for Impact Hammer testing: Force and Exponential smoothing windows added Advanced options for Force window width and Exponential window time constant Independent smoothing window selections for each channel Calibration to Force and Velocity units Trigger threshold setting now in engineering units Trigger delay can be specified in milliseconds or as percent of FFT size Option to prompt user to Accept/Reject trigger waveform Trigger preview waveform shown with smoothing window applied Overlays Increased the number of overlays from 6 to 12 with 2 composite overlays Total Power is now stored in the overlay file and marked on the wideband power bar Legend used as suggested filename when saving overlay files. Data Logging Threshold conditions: Selectable threshold condition and level for logging to occur Options to reset spectral average and peak hold after each interval New Calibration units: Acceleration m/sec^2 Velocity in/sec Velocity mm/sec Force Newtons Force lb-ft SpectraPLUS-SC version 5.3.0.0 Added Markers to Phase plot Fixed control size issue when large system fonts used Fixed playback start location when ASIO mode used Added "Set Markers" button on Data Logging setup dialog box Added "Convert To RMS Values" to right click menu on Time Series plot Use /Log folder as default location when "Export Peak Values" right click menu used SpectraPLUS-SC version 5.3.0.1 Added logic to sync DAQ input gain to wave file cal data when in post processing mode Post Processing mode時にDAQ入力ゲインをWAVファイル校正データに同期させるロジックを追加 SpectraPLUS-SC version 5.3.0.4  Signal generator sampling rate matches analyzer input rate when ASIO used DC offset calibration values stored on SpectraDAQ-200 and applied to wave data  ASIOがSpectraDAQ-200に保存されているDCオフセット校正値を使用して波形データに適用した場合、  Signal generatorのサンプリング・レートはアナライザの入力レートと一致します SpectraPLUS-SC version 5.3.0.5  Export Peak Values right click menu from time series plot - optimized calculations and added  SEL of peak event  Time Series plot右クリックメニューにピークイベントのSELを追加 Corrected SEL and Cumulative SEL units labeling  SELおよび累積SEL単位のラベリングの修正 Fixed data logging timing logic with first Leq update 最初のLeq更新でデータロギングのタイミングロジックを修正 SpectraPLUS-SC version 5.3.0.6E Added DC blocking filter DCブロッキングフィルタを追加 Fixed Signal Generator logic when decimation used デシメーションが使用されている場合のSignal Generatorのロジックを修正 SpectraPLUS-SC version 5.3.0.6F Fixed issue with data logging stopping at midnight 夜間にデータロギングが停止する問題を修正 Fixed issue with trigger threshold value parameter entry in dialog box ダイアログボックスのトリガー閾値パラメータ入力の問題を修正 SpectraPLUS-SC version 5.3.0.6G Added a Threshold Limit Line option to the time series plot 時系列プロットに閾値限界線オプションを追加 Displays a dashed horizontal line at the level specified by the user ユーザーが指定したレベルに破線の水平線を表示 これは、時系列プロットオプションダイアログボックスで設定します。 Expanded the Frequency, Level, and Total Power utility windows 周波数、レベル、およびTotal Powerユーティリティーウィンドウを拡張 If peak hold is enabled separate columns will show live and peak hold values ピークホールドを有効にすると、ライブとピークホールドの値が別々の列に表示 The values are displayed using the same color as their respective traces on the plot 値はプロット上でそれぞれのトレースと同じ色で表示 New dual channel spectral processing option: Add Left and Right デュアルチャンネル・スペクトル処理オプション: LeftとRightを追加 Computes the sum of the channels and displays on the spectrum plots チャンネルの合計を計算し,Spectrumプロットに表示 This is a vector summation (if the signals are 180 out of phase they will cancel) これはベクトル和です(信号が位相から180ずれている場合はキャンセル) New COM API commands for trigger analysis: COM APIコマンドの追加 GetTriggerCount() GetMaxValueInTriggerSeries() GetMinValueInTriggerSeries() GetTriggerTimeSeries() SpectraPLUS-SC version 5.3.0.7 Fixed Invalid Smoothing Window error condition 無効なSmoothing Windowのエラー条件を修正 Added logic and error messaging to prevent the DAQ input gain from being changed if a wave file is open ウェーブファイルを開いている時に、DAQの入力ゲインが変更されないようにするための ロジックとエラーメッセージングを追加 SpectraPLUS-SC version 5.3.0.8